APPLICATION OF THE SYSTEM FOR PREOPERATIVE MODELING BASED ON

COMPUTED TOMOGRAPHY DATA IN PATIENT WITH LIVER HYDATID DISEASE

Kolsanov A.V., Zelter P.M., Manukyan A.A., Chaplygin S.S., Kolesnik I.V.

Purpose. To explore the possibilities of preoperative modelling and analysis system based on multislice computed tomography (MSCT) data, to evaluate its effectiveness in patient with liver hydatid disease.
Samara State Medical University
Samara, Russia.

Materials and methods. MSCT data with contrast enhancement was loaded into the "Avtoplan" system. Experience of the system application in patient with liver hydatid disease has been studied.

Results. Operation right hemihepatectomy was performed considering the virtual resection line; it was proved that remaining liver volume is sufficient for functioning.

Conclusions. Pre-operative planning can solve limitations of workstations and provide a surgeon with important information on individual anatomic and topographic features.

Keywords: hydatid disease, 3D-reconstruction, computed tomography, pre-operative planning.


 

Corresponding author: Zelter P.M., Этот e-mail адрес защищен от спам-ботов, для его просмотра у Вас должен быть включен Javascript

 

For citation: Kolsanov A.V., Zelter P.M., Manukyan A.A., Chaplygin S.S., Kolesnik I.V. Application of the system for preoperative modeling based on computed tomography data in patient with liver hydatid disease. REJR. 2016; 6 (2):111-114. DOI:10.21569/2222-7415-2016-6-2-111-114.

Received: 25.02.2016 Accepted: 04.03.2016